Display Bpdu-Tunnel - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

To prevent the devices in the service provider network from processing the tunnel packets as other
protocol packets, the MAC address for tunnel packets must be a multicast address specially for
BPDU tunnels in the service provider network.
The destination MAC addresses configured at the two ends of a BPDU tunnel must be the same;
otherwise, the protocol packets cannot be transmitted and forwarded normally.
Related commands: display bpdu-tunnel.
Examples
# Set the destination MAC address for protocol packets transmitted along BPDU tunnels to
010f-e266-c3ab.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] bpdu-tunnel tunnel-dmac 010f-e266-c3ab

display bpdu-tunnel

Syntax
display bpdu-tunnel
View
Any view
Parameters
None
Description
Use the display bpdu-tunnel command to display the private multicast MAC address configured for
protocol packets transmitted along the BPDU tunnel(s).
Related commands: bpdu-tunnel tunnel-dmac.
Examples
# Display the private multicast MAC address configured for packets transmitted along the BPDU
tunnel(s).
<Sysname> display bpdu-tunnel
Tunnel packet's destination-mac-address: 010f-e2cd-0003
The above output information indicates that all the protocol packets transmitted along the BPDU
tunnel(s) use 010f-e2cd-0003 as their destination MAC addresses.
3-3

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

5500-ei series