info-center timestamp

Syntax
info-center timestamp { log | trap | debugging } { boot | date | none }
undo info-center timestamp { log | trap | debugging }
View
System view
Parameters
log: Specifies log information.
trap: Specifies trap information.
debugging: Specifies debugging information.
boot: Specifies to adopt the time elapsed since system boot, which is in the format of "xxxxxx.yyyyyy",
where xxxxxx is the high 32 bits and yyyyyy the low 32 bits of the elapsed milliseconds.
date: The current system date and time, in the format of "Mmm dd hh:mm:ss:sss yyyy".
Mmm: The abbreviations of the months in English, which could be Jan, Feb, Mar, Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, or Dec.
dd: The date, starting with a space if less than 10, for example " 7".
hh:mm:ss:sss: The local time, with hh ranging from 00 to 23, mm and ss ranging from 00 to 59, and
sss ranging from 0 to 999.
yyyy: Represents the year.
none: Specifies not to include time stamp in the specified output information.
Description
Use the info-center timestamp command to set the format of time stamp included in the
log/trap/debugging information.
Use the undo info-center timestamp command to restore the default setting of time stamp format.
By default, the date time stamp is adopted for log and trap information, and the boot time stamp is
adopted for debugging information.
Examples
# Set the boot time stamp for debugging information.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] info-center timestamp debugging boot

info-center timestamp loghost

Syntax
info-center timestamp loghost { date | no-year-date | none }
undo info-center timestamp loghost