Datafill - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

View
remote-ping test group view
Parameters
times: Number of probes in each remote-ping test. The times argument ranges from 1 to 15.
Description
Use the count command to set the number of probes in each remote-ping test.
Use the undo count command to restore the default.
For tests except jitter test, only one packet is sent in a probe. In a jitter test, you can use the
jitter-packetnum command to set the number of packets to be sent in a probe.
By default, the number of probes in each test is 1.
Related commands: frequency.
Examples
# Set the number of probes made in an ICMP test to 10.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping administrator icmp
[Sysname-remote-ping-administrator-icmp] test-type icmp
[Sysname-remote-ping-administrator-icmp] count 10

datafill

Syntax
datafill string
undo datafill
View
remote-ping test group view
Parameters
string: Data for padding test packets. It is a string of 1 to 230 characters, including spaces
Description
Use the datafill command to configure the data for padding test packets.
Use the undo datafill command to restore the default.
By default, test packets are padded with characters in the range 0 to 255 cyclically.
You can pad remote-ping test packets with a character string in the range of 1 to 230 characters,
including spaces. If the size of a test packet is smaller than that of the configured padding string, only a
portion of the data is used. If the size of the packet is larger, the string is used cyclically for padding.
Suppose a padding string, "abcd" is configured. If the test packet size is 3 bytes, only "abc" is used; if it
is 8 bytes, the string "abcdeabc" is used.