Probe-Failtimes - 3Com 5500-EI PWR Reference Manual

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

To perform an FTP test successfully, the configured password must be consistent with the FTP
user password configured on the server.
This command applies to FTP tests only.
Examples
# Set the password for logging into the FTP server as remote-ping in an FTP test.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping administrator ftp
[Sysname-remote-ping-administrator-ftp] test-type ftp
[Sysname-remote-ping-administrator-ftp] password remote-ping

probe-failtimes

Syntax
probe-failtimes times
undo probe-failtimes
View
remote-ping test group view
Parameters
times: Number of consecutive failed probes, in the range of 1 to 15.
Description
Use the probe-failtimes command to configure the number of consecutive times the probe fails before
the switch sends out a trap message.
Use the undo probe-failtimes command to restore the default.
By default, the switch sends a trap about probe failure each time when a probe fails.
Examples
# Configure the switch to send a trap after the probe in an ICMP test fails for three consecutive times.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping administrator icmp
[Sysname-remote-ping-administrator-icmp] test-type icmp
[Sysname-remote-ping-administrator-icmp] probe-failtimes 3
1-27

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

5500-ei series

Table of Contents