remote-ping test group view
Parameters
number: Number of packets to be transmitted in one probe for a jitter test, in the range of 10 to 1000.
Description
Use the jitter-packetnum command to configure the number of packets to be sent in one probe for a
jitter test.
Use the undo jitter-packetnum command to restore the default.
By default, 10 packets are sent in a probe for a jitter test.
Related commands: jitter-interval.
This command applies to jitter tests only.
Examples
# Configure to send 30 packets in a probe for a jitter test.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping administrator jitter
[Sysname-remote-ping-administrator-jitter] test-type jitter
[Sysname-remote-ping-administrator-jitter] jitter-packetnum 30

password

Syntax
password password
undo password
View
remote-ping test group view
Parameters
password: Password for logging in to an FTP server, a string of 1 to 32 characters.
Description
Use the password command to configure a password for logging in to the FTP server.
Use the undo password command to remove the configured password.
By default, the password for logging in to the FTP server is not configured.
Related commands: username, ftp-operation.
1-26