Juniper JUNOSE SOFTWARE 11.2.X - BROADBAND ACCESS CONFIGURATION GUIDE 7-20-2010 Configuration Manual page 300

Software for e series broadband services routers broadband access configuration guide
Table of Contents

Advertisement

JunosE 11.2.x Broadband Access Configuration Guide
Table 50: Juniper Networks (Vendor ID 4874) VSA Formats (continued)
Attribute
Number
Attribute Name
[26-82]
Qos-Parameters
[26-83]
Service-Session
[26-84]
Mobile-IP-Algorithm
[26-85]
Mobile-IP-SPI
[26-86]
Mobile-IP-Key
[26-87]
Mobile-IP-Replay
[26-88]
Mobile-IP-Access-
Control-List
[26-89]
Mobile-IP-Lifetime
[26-90]
L2TP-Resynch-Method
[26-91]
Tunnel-Switch-Profile
262
Description
Name of the QoS parameter instance to
create on the user's interface, followed by
the value of the parameter. For example,
the max-bandwidth 4000000 parameter
instance represents the parameter name
that was defined using the qos-parameter-
define command (max-bandwidth) and
the value to assign to the parameter
(4000000). Multiple instances of this VSA
can be returned from RADIUS using this
format.
Name of the service (including parameter
values) that is associated with service
manager statistics
Authentication algorithm used for Mobile
IP registration
Security parameter index for Mobile IP
registration
Security association MD-5 key for Mobile
IP registration
Replay time stamp for Mobile IP
registration
Access control list to filter on basis of
care-of address
Registration lifetime for Mobile IP
registration
L2TP peer resynchronization method
Name of the L2TP tunnel switch profile
The L2TP tunnel switch profile defines
the L2TP tunnel switching behavior for
the interfaces to which this profile is
assigned
Subtype
Length
Length
Value
len
sublen
string: format is
parameter name
parameter value,
where parameter
name is ASCII name of
a parameter name
found in the QoS
parameter definition
and parameter value
is the ASCII
representation of
0–21474836470;
multiple instances of
this VSA can be
returned from RADIUS
using this format
len
sublen
string:service-name
12
6
integer: 4-octet
12
6
integer: 4-octet
len
sublen
string: 32-octet
12
6
integer: 4-octet
len
sublen
string: 32-octet
12
6
integer: 4-octet
12
6
integer: 0 = disabled;
1= failover protocol;
2 = silent failover;
3 = failover protocol
with silent failover as
backup
len
sublen
string:
tunnel-switch-profile
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.2

Table of Contents