Danfoss VACON 100 FLOW Series Application Manual page 252

Hide thumbs Also See for VACON 100 FLOW Series:
Table of Contents

Advertisement

VACON® 100 FLOW
Application Guide
Parameter Descriptions
11.15.11.10 (ID 15570) Multi-setpoint 10
Location in the menu: P3.13.12.11
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.11 (ID 15571) Multi-setpoint 11
Location in the menu: P3.13.12.11
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.12 (ID 15572) Multi-setpoint 12
Location in the menu: P3.13.12.13
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.13 (ID 15573) Multi-setpoint 13
Location in the menu: P3.13.12.13
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.14 (ID 15574) Multi-setpoint 14
Location in the menu: P3.13.12.15
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.15 (ID 15575) Multi-setpoint 15
Location in the menu: P3.13.12.16
Use this parameter to set the preset PID setpoint value when the Multi-setpoint function is used. Make the selection of the multi-
setpoint with the digital input signals.
11.15.11.16 (ID 15576) Multi-setpoint Selection 0
Location in the menu: P3.13.12.17
Use this parameter to select the digital input signal that is used as a selector for the PID Multi-setpoint function.
11.15.11.17 (ID 15577) Multi-setpoint Selection 1
Location in the menu: P3.13.12.18
Use this parameter to select the digital input signal that is used as a selector for the PID Multi-setpoint function.
11.15.11.18 (ID 15578) Multi-setpoint Selection 2
Location in the menu: P3.13.12.19
Use this parameter to select the digital input signal that is used as a selector for the PID Multi-setpoint function.
11.15.11.19 (ID 15579) Multi-setpoint Selection 3
Location in the menu: P3.13.12.20
Use this parameter to select the digital input signal that is used as a selector for the PID Multi-setpoint function.
11.16 External PID Controller
11.16.1 (ID 1630) Enable External PID
Location in the menu: P3.14.1.1
Use this parameter to enable the PID controller.
This controller is for external use only. It can be used with an analog output.
252 | Danfoss A/S © 2023.08
AB298035655957en-000201 / DPD01083

Advertisement

Table of Contents
loading

Table of Contents