VACON® 100 FLOW
Application Guide
3.
Select Rem from favourites.
STOP
Monitor
Help
Rem from favourites
4.
To remove the item, push the [OK] button again.
9.3 User Levels
9.3.1 Using the User Levels Menu
Use the User level parameters to keep the personnel who are not approved from changing the parameters. Also accidental changes
in the parameters can be prevented.
When a user level is selected, the user cannot see all the parameters on the display of the control panel.
9.3.2 The User Level Parameters
Table 127: The User Level Parameters
Index
Param-
Min
Max
eter
P8.1
User
1
3
Level
P8.2
Access
0
99999
Code
Danfoss A/S © 2023.08
READY
I/O
Motor Nom Freq
Unit
De-
ID
fault
1
1194
0
2362
Description
1 = Normal. All the menus are visible in the main menu.
2 = Monitoring. Only the monitoring and user level menus are visible
in the main menu.
3 = Favourites. Only the favourites and user level menus are visible in
the main menu.
4 = Monitoring & Favourites. Monitoring, favourites and user level me-
nus are visible in the main menu.
If the value is set to be other than 0 before going to Monitoring from,
for example, Normal, the access code has to be given when going back
to Normal. This prevents personnel who are not approved from mak-
ing changes in the parameters on the control panel.
NOTE! Do not lose the access code. If the access code is lost, contact
your nearest service center or partner.
User Settings, Favourites, and User
Level Menus
AB298035655957en-000201 / DPD01083 | 149