VACON® 100 FLOW
Application Guide
Selection
Selection name
number
30
Fieldbus Control Word bit 15
31
Fieldbus Process Data In1 bit 0
32
Fieldbus Process Data In1 bit 1
33
Fieldbus Process Data In1 bit 2
34
Maintenance counter 1 alarm
35
Maintenance counter 1 fault
36
Block Out.1
37
Block Out.2
38
Block Out.3
39
Block Out.4
40
Block Out.5
41
Block Out.6
42
Block Out.7
43
Block Out.8
44
Block Out.9
45
Block Out.10
46
Jockey pump control
47
Priming pump control
48
Auto-cleaning active
49
Multi-pump K1 control
50
Multi-pump K2 control
51
Multi-pump K3 control
52
Multi-pump K4 control
53
Multi-pump K5 control
54
Multi-pump K6 control
Danfoss A/S © 2023.08
Description
The digital (relay) output control from the Fieldbus control word bit 15.
The digital (relay) output control from the Fieldbus Process Data In1, bit 0.
The digital (relay) output control from the Fieldbus Process Data In1, bit 1.
The digital (relay) output control from the Fieldbus Process Data In1, bit 2.
The maintenance counter reached the alarm limit that is set with parameter
P3.16.2.
The maintenance counter reached the alarm limit that is set with parameter
P3.16.3.
The output of the programmable Block 1. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 2. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 3. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 4. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 5. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 6. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 7. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 8. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 9. See parameter menu M3.19 Drive cus-
tomizer.
The output of the programmable Block 10. See parameter menu M3.19 Drive cus-
tomizer.
The control signal for the external jockey pump.
The control signal for the external priming pump.
The Pump auto-cleaning function is activated.
The contactor control for the Multi-pump function.
The contactor control for the Multi-pump function.
The contactor control for the Multi-pump function.
The contactor control for the Multi-pump function.
The contactor control for the Multi-pump function.
The contactor control for the Multi-pump function.
Parameter Descriptions
AB298035655957en-000201 / DPD01083 | 211