Serial port
rs-232
n
rs-485
n
l
The default is rs-232.
6. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure PPP dial-in mode

PPP dial-in allows the device to answer Point-to-Point Protocol (PPP) connections over serial ports.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in
device.
b. Click the Device ID.
c. Click Settings.
d. Click to expand Config.
Web UI:
a. On the menu, click System. Under Configuration, click Device Configuration.
IX10 User Guide
Enable termination if you want to enable electrical termination on this serial port:
(config)> serial port1 termination true
(config)>
Use Digi Remote Manager to view and manage your
Configure PPP dial-in mode
173