16-bit Multi-Purpose Timer G (TMG)
Downloaded from
Elcodis.com
electronic components distributor
(b) When 0000H is set in GCCnm (match and clear)
When 0000H is set in GCCnm, TOGnm is tied to the inactive level.
The figure below shows the state of TOGn1 when 0000H is set in GCCn1, and
TMGn0 is selected.
Note, however, that 0FFFH is set in GCCn0.
ENFG0
0FFFH
Ma tch
TM G n0
GCCn1
INTTGnCC1
INTGnCC0
Low
TOGn1(ALVG1=1)
TOGn1(ALVG1=0)
High
Figure 13-16
Timing when 0000H is set in GCCnm (match and clear)
Preliminary User's Manual U17566EE1V2UM00
0FFFH
0FFFH
0000H
Chapter 13
469