Setting Items
MC ID CODE
Check just the SEs shared via multiple MCs when connected to FUJIFILM APs.
The "MC_ID_MODE" checks that other MCs are not redundant, and makes changes if
they are redundant.
EDIT RU NAME
Input the RU name.
u NOTE u
The RU maximum input character count is 15 one-byte characters.
CSL MAC ADDRESS (xx:xx:xx:xx:xx:xx)
Inputs the MAC address [Default: 00:00:00:00:00:00].
u NOTE u
If the PC for MC is available, input this MAC address after starting the DX Console
with the Wake on LAN when turning ON the MC power.
REFERENCE
<How to display the MAC address>
(1) Press the Windows key and the [R] key concurrently.
→ The "Run..." window opens.
(2) Input "cmd/k ipconfig/all", and click [OK]. ( indicates a space.)
→ The MAC address appears in "Physical Address" of the "Ethernet adapter Local
Area Connection:" block.
CSL IP ADDRESS (xxx.xxx.xxx.xxx)
Inputs the IP address [Default: 127.0.0.7].
u NOTE u
If the PC for MC is available, change its IP address.
018-234-04E
OPE SETTING (UPRIGHT)
Specifies to which MP the X-ray shot cable corresponding to the operative method
[Stand] of the X-ray equipment is to be connected.
<Options>
- None:
- MP1 [default]:
- MP2:
{ OPE SETTING (UPRIGHT/TABLE/FREE)}
OPE SETTING (TABLE)
Specifies to which MP the X-ray shot cable corresponding to the operative method [Bed]
of the X-ray equipment is to be connected.
<Options>
- None:
- MP1 [default]:
- MP2:
{ OPE SETTING (UPRIGHT/TABLE/FREE)}
OPE SETTING (FREE)
Specifies to which MP the X-ray shot cable corresponding to the operative method
[FREE (general)] of the X-ray equipment is to be connected.
<Options>
- None:
- MP1 [default]:
- MP2:
{ OPE SETTING (UPRIGHT/TABLE/FREE)}
PORT SETTING (UPRIGHT)
Specifies to which terminal block the X-ray shot cable corresponding to the operative
method [Stand] of the X-ray equipment is to be connected.
<Options>
- MPX1 [default]:
- MPX2:
DR-ID 1300 / DR-ID 1300PU Service Manual
Not connected
Connected to MP1
Connected to MP2
Not connected
Connected to MP1
Connected to MP2
Not connected
Connected to MP1
Connected to MP2
Connected to MPX1
Connected to MPX2
MU1-12
MU1-12