Table of Contents

Advertisement

Fuji Photo Film Co., Ltd.
11.2005 897N0565
(CR-IR 355RU)
Operation Manual
First Edition: November 2005
This Operation Manual describes details on how to operate the FCR XC-1
(CR-IR 355RU) and cautions to be observed when operating it.
Please read the Operation Manual thoroughly before actually operating the
FCR XC-1 (CR-IR 355RU) system. After reading this manual, store it nearby
the FCR XC-1 (CR-IR 355RU) so that you can see it whenever necessary.
1
For Safe Operation
2
Product Overview
3
Basic Operation
4
Utility
5
Troubleshooting
6
Care and Maintenance
Appendix
Maintenance and
Inspection
Index

Advertisement

Table of Contents
loading

Summary of Contents for FujiFilm FCR XC-1

  • Page 1 (CR-IR 355RU) and cautions to be observed when operating it. Please read the Operation Manual thoroughly before actually operating the FCR XC-1 (CR-IR 355RU) system. After reading this manual, store it nearby the FCR XC-1 (CR-IR 355RU) so that you can see it whenever necessary. 11.2005 897N0565...
  • Page 2 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 3 Introduction The indications for use of the FCR XC-1 (CR-IR 355RU) Image Reader with Imaging Plate (IP) reading is the identification, capture, digitization, and processing of diagnostic X-ray images of human anatomy, and associating patient and exam identification with the images.
  • Page 4 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 5 Care and Maintenance Chapter This chapter describes daily checks and maintenance you are advised to perform so that you can use the FCR XC-1 (CR-IR 355RU) in optimum working conditions. Appendixs A Specifications...
  • Page 6 Display window A window displayed on the Operation Panel while the equipment is in operation. ��� ��� ���� ��������� ������ ����� ������ ������� �������� Page number Displayed in conjunction with the chapter number. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 7 ●Windows (example) --------------- “Utility Top” window ●Messages (example) ------------------- <Take out the cassette.> Windows Use the buttons located below the selection-menu display area for manipulation purposes. Selection menu Button First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 8: Table Of Contents

    3.2.1 Starting Up the System ............3.2.2 Shutting Down the System............. 3.2.3 Reading Cassette Images ............3.3 Starting Up/Shutting Down the FCR XC-1 Main Unit ..Utility Chapter 4.1 Starting Up and Quitting the Utility........4.2 Cleaning the Scanner............. viii First Edtion 11.2005 897N0565...
  • Page 9 Troubleshooting Chapter 5.1 Troubleshooting ..............5.2 If the FCR XC-1 Cannot be Powered ON ......5.3 If the FCR XC-1 Cannot be Powered OFF......5.4 When An Error Message Appears......... 5.5 When Image Is Streaked............Care and Maintenance Chapter 6.1 About Performing Daily Checks and Maintenance ....
  • Page 10 1.5 EDR Image Data Analysis ............2 Precautions for Exposure in the SEMI-AUTO MODE ..... 3 Precautions for Exposure in the SEMI-X MODE ......4 Precautions for Exposure in the FIX MODE ........Maintenance and Inspection Index First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 11 1.2 Precautions to be Observed When Using the Electric Medical Equipment __________________________ 1.3 Safety _________________________________________________ 1.4 Electromagnetic Compatibility (EMC) ____________________ 1.5 Precautions to Take When Using the FCR XC-1 (CR-IR 355RU) _________________________________________ 1-10 1.6 Location of Each Label _________________________________ 1-12 First Edtion 11.2005 897N0565...
  • Page 12: Precautions Before Operating This Equipment

    This equipment has been designed on the assumption that the patient would not come into direct contact with it or for operation by appropriately trained operator. Process waste correctly, as stipulated by local law or any regulations that apply. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 13: Precautions To Be Observed When Using The Electric Medical Equipment

    8-1. When subjecting patients (particularly infants and pregnant women) to radiation, make sure not to exceed the necessary time and dose. Also, ensure that radiation is contained within the region for exposure. 8-2. Follow the Operation Manual and operate the equipment correctly. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 14: Safety

    Wavelength : 660 nm Maximum Output : 50 mW (CW) The FCR XC-1 (CR-IR 355RU) incorporates a Class 3B laser with maximum output of 50mW. To prevent exposure to its laser beams, observe the following precautions. ● Never open or remove the protective covers.
  • Page 15 ● When using the equipment within the environment where the patient may get into touch with it, optionally connect additional protective earth conductor (FCR XC-1 (CR-IR 3555RU)). ● When using the equipment within the environment where the patient may get into touch with it, connect the power supply unit to a medical-use plug via an optional insulating power transformer (CR Console (CR-IR 348CL)).
  • Page 16 • The FCR XC-1 (CR-IR 355RU) should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the FCR XC-1 (CR-IR 355RU) should be observed to verify normal operation in the configuration in which it will be used.
  • Page 17 field typical location in a typical commercial IEC61000-4-8 or hospital environment. NOTE: U is the a.c. mains voltage prior to application of the test level. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 18 CR-IR 355RU should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the CR-IR 355RU. b Over the frequency range 150 kHz to 80 MHz, field strength should be less than 3 V/m. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 19 NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 20: Precautions To Take When Using The Fcr Xc-1 (Cr-Ir 355Ru)

    14. Do not subject the equipment or cassette to vibration while an image is being read. Otherwise, an image with unevenness or the like may be output, which will adversely affect image reading. 15. When you install the FCR XC-1 (CR-IR 355RU) close to a wall, use caution not to block its air outlet openings.
  • Page 21 16. Clean the air outlet openings periodically to keep them clear of dust or the like which can cause blocking. If they are blocked, the temperature inside the FCR XC-1 (CR-IR 355RU) rises abnormally high and the image on the IP may be imperfectly erased, possibly causing an output image that does not allow accurate image interpretation.
  • Page 22: Location Of Each Label

    1.6 Location of Each Label Shown below are the positions where the FCR XC-1 (CR-IR 355RU) labels are affixed. HHS Certification and Identification Label IEC60825-1: 2001/ Rating Label EN60825-1: 2002 Class 3B Panel Label IEC60825-1: 2001/EN60825-1: 2002 Class 3B Panel Label...
  • Page 23: Product Overview

    Chapter Product Overview Pages 2.1 Features of the FCR XC-1 (CR-IR 355RU) _________________ 2.2 Units Names and the Functions __________________________ _____________________ 2.2.1 FCR XC-1 (CR-IR 355RU) Main Unit ____________________________________ 2.2.2 Operation Panel ___________________________________________ 2.2.3 Display _______________________________ 2.2.4 Processing Status Bar First Edtion 11.2005 897N0565...
  • Page 24: Features Of The Fcr Xc-1 (Cr-Ir 355Ru)

    5 Exposure information items that include patient information, anatomical regions and exposure menus can be entered on the console connected to the FCR XC-1 (CR-IR 355RU). 6 Since the FCR XC-1 (CR-IR 355RU) is designed to have a small depth, it can be installed in relatively tight spaces.
  • Page 25 The FCR XC-1 (CR-IR 355RU) can be network-connected to a Console or printer or the like. Illustrated below is an example of system configurations for the connected for FCR XC-1 (CR-IR 355RU) and Console. Accessory equipment connected to the analog and digital interfaces must be in compliance with the respective nationally harmonized IEC standards (i.e.
  • Page 26: Units Names And The Functions

    2.2 Units Names and the Functions Described below are units component of the FCR XC-1 (CR-IR 355RU) main unit and the Operation Panel. Also presented are configuration of windows that open during the operation and error display configuration. 2.2.1 FCR XC-1 (CR-IR 355RU) Main Unit...
  • Page 27: Operation Panel

    When the error has been resolved, the lamp goes off. Power ON Switch Turns on/off the power to the FCR XC-1 (CR-IR 355RU). This button is used when the FCR XC-1 (CR-IR 355RU) is started up singly.
  • Page 28: Display

    Displays the status of processing operations being performed on the inserted cassette. For details, see page 2-8. Selection-menu Display Field A menu of user-selectable options (buttons) are displayed. Pressing a menu-selection key executes the function assigned to that button. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 29 Displays a message prompting the user to perform an operation. Selection-menu Display Field A menu of user-selectable options (buttons) are displayed. Pressing a menu-selection key executes the function assigned to that button. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 30: Processing Status Bar

    Reading begins - Erasure begins Lights LEVEL 3 (1) Erasure in process - Erasure completed Lights LEVEL 3 (2) Erasure completed - IP processing completed Blinks LEVEL 4 IP processing completed (cassette removal awaited) Blinks First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 31: Basic Operation

    3.2 System Startup/Shutdown and Image Reading (CR Console) __________________________________________ _______________________________ 3.2.1 Starting Up the System ____________________________ 3.2.2 Shutting Down the System _____________________________ 3.2.3 Reading Cassette Images 3.3 Starting Up/Shutting Down the FCR XC-1 Main Unit _______ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 32: Before Use

    Press [Erase] on the “Initial screen.” Take the cassette out. The “Erase image?” window appears. Press the [Execute] button. The image erasure session is complete and it automatically return to the “Initial screen.” A message will appear. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 33: System Startup/Shutdown And Image Reading (Cr Console)

    3.2 System Startup/Shutdown and Image Reading (CR Console) The startup and shutdown of the FCR XC-1 (CR-IR 355RU) is performed under the control of the CR Console’s power ON/OFF switch. To start up only the FCR XC-1 (CR-IR 355RU), use the procedure described in [3.3 Starting Up/Shutting Down the FCR XC-1 Main Unit].
  • Page 34: Shutting Down The System

    3.2.2 Shutting Down the System Turn the monitor OFF. After making certain that the FCR XC-1 has finished reading the cassette, take the cassette out. For the operation of the CR Console and the User Utility, refer to the appropriate sections of the “CR Console Operation Manual,”...
  • Page 35: Reading Cassette Images

    Read the exposed image. (FCR XC-1) Cassette guide Barcode window Explained below is the procedure to read images of a cassette inserted into the FCR XC-1. Insert straight carefully. Confirm that the Cassette Ready Lamp is lit (green) on the operation panel.
  • Page 36: Starting Up/Shutting Down The Fcr Xc-1 Main Unit

    3.3 Starting Up/Shutting Down the FCR XC-1 Main Unit This section explains how to start up/shut down the FCR XC-1 main unit. To operate the CR Console, use the procedure described in “3.2.1 Starting Up the System.” To shut down the FCR XC-1 main unit Ensure that the Main Power Switch of the FCR XC-1 has been turned ON.
  • Page 37: Utility

    Chapter Utility Pages 4.1 Starting Up and Quitting the Utility _______________________ 4.2 Cleaning the Scanner ___________________________________ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 38: Starting Up And Quitting The Utility

    4.1 Starting Up and Quitting the Utility Described herein is the procedure used to start/quit the utility for the FCR XC-1. Starting Up the Utility Quitting the Utility On the “Initial screen” press the [Utility] On the “Utility TOP” window press the [Back] button.
  • Page 39: Cleaning The Scanner

    4.2 Cleaning the Scanner You can clean the FCR XC-1’s built-in scanner. On the “Utility TOP” window, select [Scanner When the scanner cleaning completion Cleaning] and press the [OK] button. appears, press the [Confirm] button. The “Scanner Cleaning” window appears.
  • Page 40 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 41 Chapter Troubleshooting Pages 5.1 Troubleshooting ________________________________________ 5.2 If the FCR XC-1 Cannot be Powered ON __________________ 5.3 If the FCR XC-1 Cannot be Powered OFF _________________ 5.4 When An Error Message Appears ________________________ 5.5 When Image Is Streaked ________________________________ First Edtion 11.2005 897N0565...
  • Page 42: Troubleshooting

    In case you encounter any trouble you cannot handle, please contact your local authorized distributor. In Case a Problem May Arise If the FCR XC-1 Cannot be Powered ON Page 5-3 If the FCR XC-1 Cannot be Powered OFF...
  • Page 43: If The Fcr Xc-1 Cannot Be Powered On

    5.2 If the FCR XC-1 Cannot be Powered ON If the FCR XC-1 cannot be powered ON even when you have pressed the POWER button, please make the following checks: The Main Power Switch Set the Main Power Switch to the “I” side to has been turned OFF.
  • Page 44: If The Fcr Xc-1 Cannot Be Powered Off

    5.3 If the FCR XC-1 Cannot be Powered OFF If the FCR XC-1 cannot be powered off even when you have performed normal shutdown procedures, please make the following checks: Isn’t there any yet-to- Shut down the FCR XC-1 after transmitting be-transmitted image any remaining image.
  • Page 45: When An Error Message Appears

    5.4 When An Error Message Appears This section provides a listing of error messages that can appear on the screen of the FCR XC-1 along with their meanings and examples of ways of dealing with them. Should you encounter any trouble you cannot handle, contact your local authorized distributor.
  • Page 46 Remove the cassette. Register patient information from the PatientInfo Patient information is not 11511 console and then insert the registered yet. unregistered cassette again to have the image scanned. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 47 Worn pump replacing as soon as possible. distributor. Information for maintenance Maintenance data Start up the console that is 11907 checkup purposes cannot be saving failure connected to the FCR XC-1. collected. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 48 Wait until processing is complete, Cannot turn off power because of — Can’t power off and then perform termination ongoing processing. procedure. * The xxx portion varies depending on the error encountered. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 49: When Image Is Streaked

    5.5 When Image Is Streaked This section provides an example of a streaked image scanned with the FCR XC-1 and an explanation of how to fix the streaking problem. If there is soil on the scanner, an IP or both of them, a scanned image may be streaked as shown below.
  • Page 50 5-10 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 51 Care and Maintenance Pages 6.1 About Performing Daily Checks and Maintenance _________ 6.2 Cleaning the Cassette Set Unit __________________________ 6.3 Cleaning the Air Intakes and Exhaust Ports _______________ 6.4 Users Checksheet ______________________________________ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 52: About Performing Daily Checks And Maintenance

    In order to use the FCR XC-1 always in good working order, perform daily checks and maintenance on it. As for the daily checks, make certain that the FCR XC-1 starts up normally and all equipment that is connected to the FCR XC-1 can communicate normally with the FCR XC-1. For daily care, clean the cassette set unit and air intakes and exhaust ports everyday.
  • Page 53: Cleaning The Cassette Set Unit

    6.2 Cleaning the Cassette Set Unit Perform cleaning, taking care not to let dust into the FCR XC-1. Clean the dust-proof cover with a soft cloth moistened with water or the like. Dust-proof cover Do not use chemicals such as alcohol and paint thinner since they may cause deformation of the dust cover.
  • Page 54: Cleaning The Air Intakes And Exhaust Ports

    Use a vacuum cleaner to clean the front and back of the air filter, louvers and air intakes. Reattach the air filter to the upper louver. When remounting the louver, be careful not to Air filter pinch your fingers. Reattach First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 55: Users Checksheet

    Every six Does the S value remain constant? months ● Cleaning Unit for cleaning Frequency Date of cleaning Every three Cassette set unit months Every three Air intakes and exhaust ports months First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 56 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 57: Appendix

    Processing capacity _____________ Time required for monitor image display ______________ (3) Time required for generating film prints __________________ Required specifications and other ____________________________ A.1.3 Applicable Safety Standard A.2 External View and Weight _______________________________ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 58 Used for ST-VI and ST-VN 14"×17" (35×43cm), 14"×14" (35×35cm), 10"×12" (25.2×30.3cm), 8"×10" (20.1×25.2cm), 24×30cm, 18×24cm (2) Cassette FujiFilm IP Cassette CC (ST type cassette) 14"×17" (35×43cm), 14"×14" (35×35cm), 10"×12" (25.2×30.3cm), 8"×10" (20.1×25.2cm), 24×30cm, 18×24cm FujiFilm IP Cassette LC (for long-view exposure) 14"×17"...
  • Page 59 Between 66.2% and 54.2% at 1cy/mm (825.6nC/kg of X-rays) * The guaranteed initial center value is 60.0% for the six years of the equipment’s effective life time. Artifact : Should be free of image unevenness that may affect the diagnosis. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 60: Applicable Safety Standard

    Safety of laser products - Part 1 : Equipment classification, Ed. 1. 2 : 2001 requirements and user’s guide EN 60825-1 Safety of laser products - Part 1 : Equipment classification, Ed. 1. 2 : 2002 requirements and user’s guide First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 61: External View And Weight

    FCR XC-1 (CR-IR 355RU) * Dimensions: Projections are not included. (Unit : mm) <Top view> <Front view> <Left-side view> Specifications, external dimensions and weight are subject to change for improvement without prior notice. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 62 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 63: Appendix

    Appendix IP Handling Pages IP Image Erasure Operation _____________________________ Handling, Daily Care, and Storage of IPs _________________ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 64: Ip Image Erasure Operation

    floors and walls. If such an energy-loaded IP is used as-is, image degradation may result. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 65: Handling, Daily Care, And Storage Of Ips

    • Never use plastic erasers and other solvents. • Do not dig your finger nails into IP surfaces. Never expose an IP to light, which has been exposed but not scanned yet. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 66 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 67: About Text Information Printed On Film

    Appendix About Text Information Printed on Film First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 68 SCALE: 50% RT-04 1.0 AP (8) Image reversal mark (17) Set processing information (12) Time of exposure (6) Exposure menu name (16) Reduction ratio (11) Date of exposure (7) Standardization conditions + correction item First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 69 (15) Age or Date of birth his/her birth date is displayed. The image’s reduction ratio, from the life size on down, is (16) Reduction ratio displayed. (17) Set processing information The image’s batch processing information is displayed. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 70 SKALE: 50% RT-04 (17) Set processing (8) Image reversal mark information (11) Date of exposure (16) Reduction ratio (6) Exposure menu name (12) Time of exposure (7) Standardization conditions + correction item First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 71 (15) Age or Date of birth his/her birth date is displayed. The image’s reduction ratio, from the life size on down, is (16) Reduction ratio displayed. (17) Set processing information The image’s batch processing information is displayed. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 72 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 73: Image Processing Parameters

    Appndix Image Processing Parameters Pages Exposed Anatomical Regions/ Applicable Menus/Display Parameters _____________ Flexible Noise Control Software Parameters ______ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 74 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 75: Exposed Anatomical Regions/Applicable Menus/Display Parameters

    Appendix Exposed Anatomical Regions/ Applicable Menus/Display Parameters First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 76 Tomography of paranasal sinus (AP) 1 2001 Tomography of inner and middle ear (PA) SELLA TURCICA 1 2002 Tomography of turkish saddle (PA) MANDIBULAR JOINTT :T 1 2003 Tomography of gnathic joint and mandible (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 77 R 1.0 1.0 A 0.6 0.0 4 R 7.0 1.2 0.9 0.5 4 R 1.0 2.2 200 0.9 0.5 4 R 1.0 1.0 A 0.6 0.0 4 R 7.0 1.2 0.9 0.5 4 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 78 2 0016 exposure (PA) PANTOMO. 2 2004 Pantomography (PA) HEAD, MAG Magnification and magnification tomography of the inner ear, 2 6001 (PA) auditory ossicle, and other organs with 3� or higher power First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 79 Q 0.5 1.0 A 1.2 0.0 7 Q 3.0 1.2 A 1.2 0.0 7 Q 6.0 2.2 200 0.9 0.5 3 R 1.0 1.0 A 0.6 0.0 3 R 5.0 1.2 0.9 0.5 3 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 80 THORA C., MYELO Thoracic spinal canal and extradural space exposure with a 2 1107 contrast medium (AP) CERVIC., MAG 3× or more magnification of the pharynx, larynx, and other 2 4100 organs (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 81 P 1.0 1.0 A 0.5 0.1 5 P 5.0 1.0 F 0.6 0.5 5 P 1.0 2.4 200 2.0 0.3 3 R 1.0 1.0 A 1.9 0.4 3 R 5.0 1.0 2.0 0.3 3 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 82 Plain thoracic exposure; observation of the lung field and 1 0280 mediastinum for shadows with grid (AP) CHEST, LINE PLCMT Plain thoracic exposure; observation of the lung field and 1 0290 mediastinum for shadows (PA) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 83 R 5.0 0.8 E 1.6 0.0 4 R 0.5 2.2 200 0.8 E 1.6 0.0 4 R 0.5 0.9 A 1.5 0.0 4 R 5.0 0.8 E 1.6 0.0 4 R 0.5 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 84 SHLD, JNT, ARTHRO 2 1208 Shoulder joint exposure with a contrast medium Use a grid. (AP) CHEST, MAG 3× or more magnification of the lung field, thoracic 2 4208 lymphoduct, and other sites (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 85 T 5.0 1.2 G 0.6 0.25 5 T 1.0 2.0 200 1.2 E 1.6 -0.2 3 R 1.0 0.9 A 1.5 -0.2 3 R 5.0 1.0 E 1.6 -0.2 3 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 86 Abdominal lymphatic duct and lymph node exposure with a 2 1406 contrast medium (AP) ABDOMEN, MAG 3× or more magnification of the abdominal lymphatic duct, 2 5406 bones, and other organs (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 87 T 5.0 1.1 D 0.6 0.4 5 T 1.0 2.0 200 1.1 D 0.6 0.4 4 R 1.0 0.9 A 0.5 0.0 4 T 5.0 1.1 D 0.6 0.4 4 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 88 HIP J., PED.-1 Low-dose infantile hip joint exposure (Use the FIX MODE 2 051A when protector is used.) (AP) HIP, X-TABLE LAT. 2 050C Observation of the hip joint by axial projection (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 89 R 0.0 1.3 D 1.6 0.2 7 X 0.4 2.0 200 1.3 D 1.6 0.4 5 T 0.5 0.8 O 1.6 0.4 5 T 1.0 1.3 D 1.6 0.4 5 T 0.5 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 90 HIP JNT, ARTHRO. 2 1507 Hip joint exposure with a contrast medium (AP) PELVIS, MAG 3× or more magnification of the pelvic lymphatic duct, bone, 2 5506 and other organs (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 91 T 5.0 1.3 D 1.6 0.5 4 T 1.0 2.0 200 0.9 O 0.6 0.5 5 R 1.0 1.0 A 0.5 0.0 5 T 5.0 0.9 O 0.6 0.5 5 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 92 WRIST JNT, ARTHRO :C 2 1622 Exposure of the joint of the hand with a contrast medium (AP) UP. EXTREMITY, MAG :M 2 4607 3× or more magnification of the phalanges and other bones (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 93 T 1.0 1.0 A 0.8 0.0 3 T 5.0 0.8 O 0.6 0.2 3 T 1.5 2.0 200 0.6 0.3 5 R 1.0 0.9 A 0.7 0.1 5 R 5.0 1.1 0.6 0.3 5 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 94 FOOT, LYMPHA Exposure of the lymphatic duct and lymph node of the foot 2 1712 with a contrast medium (AP) KNEE JNT, ARTHRO 2 1720 Knee joint exposure with a contrast medium (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 95 T 5.0 0.7 O 0.6 0.4 4 T 1.5 2.0 200 1.0 O 0.6 0.5 3 T 1.0 1.0 A 0.6 0.1 3 T 5.0 0.8 O 0.6 0.5 3 T 1.5 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 96 PATL. AXL., ARTHRO :C Exposure of patellar with a contrast medium by axial 2 071B projection (AP) LO. EXTREMITY, MAG :M 2 4707 3× or more magnification of the toe and other sites (AP) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 97 T 1.0 0.7 A 2.0 -0.5 3 T 7.0 1.1 F 2.0 0.0 3 T 1.0 2.0 200 0.6 -0.1 5 R 1.0 0.9 A 1.0 0.0 5 R 5.0 1.1 0.6 -0.1 5 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 98 Auto Mode. This is to output images in 0.8 (GT:A) of density for Semi III Auto V (Dmin = 0.0) using the Type II S 1 5903 AVE5RB08 (RB). the Auto Mode. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 99 R 1.0 1.0 E 1.6 -0.2 4 R 1.0 V III(RB) 2.0 200 1.0 E 1.6 -0.2 4 R 1.0 1.0 E 1.6 0.0 4 R 1.0 1.0 E 1.6 -0.2 4 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 100 Auto Mode. This is to output images in 1.6 (GT:A) of density for Semi III Auto IV (Dmax = 1.8) using the Type I S 1 7908 AVE5CM16 (CM). in the Auto Mode. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 101 R 1.0 1.0 E 1.6 -0.2 4 R 1.0 IV III(CM) 2.0 200 1.0 E 1.6 -0.2 4 R 1.0 1.0 E 1.6 0.0 4 R 1.0 1.0 E 1.6 -0.2 4 R 1.0 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 102 Observation of the phalanges and peripheral soft parts (AP) ELBOW 1 0610 Observation of the elbow (AP) WRIST 1 0611 Observation of wrist and wrist joint (AP) 1 0616 HAND, LATERAL(AP) Observation of hand lateral First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 103 2.2 200 2.2 200 2.2 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 2.0 200 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 104 Observation of the knee joint for lateral position Mainly tomography of the lung field; observation of the lung 1 2200 LUNG field and rib Observation of the whole breast Available for other 1 0300 BREAST(PA) exposures including spot exposure First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 105 DRN DRT DRE ORN ORT ORE DRN DRT DRE ORN ORT ORE DRN DRT DRE ORN ORT ORE 2.0 200 2.0 200 2.0 200 2.0 200 2.6 200 2.0 200 2.0 200 2.0 200 2.0 200 2.2 200 1.8 40 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 106 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 107: Flexible Noise Control Software Parameters

    Appendix Flexible Noise Control Software Parameters First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 108 “A” controls noise over the entire gamut of frequency components, from low to high. As the parameter value proceeds toward “F,” FNC is applied predominantly to higher frequency components. 0.001 0.01 Frequency (cy/mm) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 109 FNC-applied images, enhancement will be able to be applied to them to a greater degree than to conventionally prepared images. (With noise being approximately the same as before, greater signal enhancement is possible.) First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 110 S values by using an appropriately controlled X-ray generator to perform exposures and checking those values detected on image data read under certain conditions. The guideline to be adopted is about twice the control range. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 111 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 112 Sacrum/Coccyx, Frn; Sacrum/Coccyx, Lat; Sacroiliac Jnt, Frn; Sacroiliac SACRUM/COCCYX 0502 Jnt, Obl; Ischium, Frn; Ischium, Lat; Sacrum, Frn; Sacrum, Lat; Coccyx, Frn; Coccyx, Lat HIP JNT 0508 Hip Jnt, Frn; Lauenstein PELVIMETRY 0504 Guthmann; Martius First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 113 Left Image 0.60 0.25 Right Image – – – – 0.60 0.10 One image 0.60 0.25 Left Image 0.60 0.20 Right Image – – – – 0.70 0.00 One image 0.60 0.20 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 114 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 115: Precautions For Exposure

    Appendix Precautions for Exposure Pages Precautions to Take Before Exposure _________________________ Precautions to Take in Each Mode ____________________________ First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 116: Precautions To Take Before Exposure

    When carrying out exposure using a stationary grid, it is recommended to use a 60 lines/cm grid with fewer artifacts. Use a grid whose line direction is parallel to the cassette’s vertical direction (between top and bottom). Green mark Bottom Cassette First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 117: Precautions To Take In Each Mode

    • Do not set the radiation field extremely small. Be sure to expose X-rays on one thirds or more of the length of each side of the IP. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 118 • The radiation field must not include the whole head. Be sure to secure transparent portions on both sides of the neck. Femur side 1/12 Use the “Skull, General” menu to include the whole head in the radiation field. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 119: Cautions For "Pantomo" X-Ray Exposures Using A 10"×12" Cassette

    IP as equal as possible (maximum 1.6 times). In other words, for multiple exposures, submit each portion of the IP to the appropriate exposure dose according to the intended anatomical region as usual. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 120: Precautions For Exposure In The Semi-Auto Mode

    FIX MODE. Thus, select the exposure conditions that correspond to that menu. Area Center Coordinate (x:y) cm Size (cm) (0, 0) 10×10 (-5, 7) 6×6 (5, 7) 6×6 (-5, -7) 6×6 (5, -7) 6×6 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 121: Maintenance And Inspection

    Maintenance and Inspection 1 Maintenance and Inspection Items Assigned to Specified Dealer For periodical inspection of the equipment and necessary arrangements, consult our official dealer or local representative. First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 122 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 123: Index

    External Device Connector ......2-4 Starting Up the System ......3-3 Starting Up the Utility......... 4-2 Storage conditions ........B-3 FCR XC-1 (CR-IR 355RU)......2-2 Title Display Field....... 2-7, 5-5 Title/Message Display Field ....... 2-6 Image erasure ........... 3-2 Imaging plate..........2-2 Information to be printed on film ....
  • Page 124 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 125 First Edtion 11.2005 897N0565 FCR XC-1 Operation Manual...
  • Page 126 FUJIFILM MEDICAL SYSTEMS U.S.A., INC. 419 WEST AVENUE, STAMFORD CT 06902, U.S.A.

This manual is also suitable for:

Cr-ir 355ru

Table of Contents