Asai-Res/E-Dig-Res (Tn800 Reserve Slot) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

ASAI-RES/E-DIG-RES (TN800 reserve slot)

ASAI-RES/E-DIG-RES (TN800 reserve
slot)
MO Name (in
Alarm Log)
ASAI-RES
E-DIG-RES
There are no tests associated with these MOs. Both the test board and busy out
board commands abort when either is attempted on a reserved slot. An error
message indicates the slot is associated with the circuit pack that the TN800 is
emulating, but the requested operation is not valid.
The TN800 MAPD (Multi-Application Platform for DEFINITY) circuit pack
connects to the switch through a single slot in the backplane. The number of slots
occupied by the MAPD pack is supplied by the board when inserted. The TN800
in R5EM is 3 slots wide. The TN800 requires 2 reserve slots to its left. The reserve
(blank) slots are to left of the functional slot and are place holders on the switch,
and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective
circuit pack mode in which the MAPD is working.
555-233-123
Alarm
Initial Command to
Level
Run
NONE
NONE
NONE
NONE
Full Name of MO
TN800 ASAI reserve slot
TN800 DIG reserve slot
Issue 4 May 2002
10-193

Advertisement

Table of Contents
loading

Table of Contents