Avaya Definity SI Maintenance Manual page 828

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-16. TEST #161 Loop Around Test — Continued
Error
Code
Result
1018
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
10-42
Issue 4 May 2002
Test
Test disabled by administration. To enable the test for the
particular analog station being tested, enter the change station
<extension> command and change the
Station Form from
Response to the test request was not received within the
allowable time period.
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
The reflective Loop Around Test failed. This causes noisy or
unreliable connections or other users calling this port may hear
an echo.
1. Replace the circuit pack.
The port is able to provide an analog transmission path to the
station equipment. User-reported troubles on this port should be
investigated by using other port tests, by examining station
wiring, or by examining the station.
Description/Recommendation
Test?
to y.
n
Continued on next page
field on the
555-233-123

Advertisement

Table of Contents
loading

Table of Contents