AN-LN-PT (Analog Line Port)

AN-LN-PT (Analog Line
Port)
MO Name (in
Alarm Log)
AN-LN-PT
AN-LN-PT
1
UU is the universal cabinet number (1 for PPN, 2 -3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, etc.).
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID), and the TN797
Analog Trunk and Line circuit pack both support this Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports
for voice terminals and supports both on-premises and off-premises analog voice
terminals.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which
may be administered in any of several ways, as described in maintenance object
TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data
modules. When assigned, analog data modules provide access to the
NetPkt (TN2401/TN794 circuit pack) data ports. To activate an analog data
module you must assign the port location on the data form and connect a
modem to the port. The analog data module can be used for connection to a
CDR output, or other adjuncts as needed. These ports are tested the same
as all other analog ports on the circuit pack.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the Tests field of the change station extension form. Be aware that
this action also disables Tests #6, 7, 161, and 35 on some software releases.
555-233-123
Initial Command to
1
Alarm Level
Run
MIN
test port UUCSSpp l
WRN
test port UUCSSpp sh
Full Name of MO
Analog Line Port
Analog Line Port
Issue 4 May 2002
10-111