status bri-port

status bri-port
This command displays the service state, maintenance state and layer 1 state of
an ISDN-BRI port. This form also displays information about point-to-point
signaling links that transport over the port.
Action/Object
Qualifier
status bri-port
location
print
Output
The following example shows the output from status bri-port 1c1701.
status bri-port 1c1701
Port: 01C1701
Service State: in-service
Maintenance Busy?: no
Layer 1 State: activated
TEI Value
Layer2 State
Link1
64
13-established
Link2
Link3
Field descriptions
Port
Service
State
Maintenance
Busy
555-233-123
Qualifier Description
Physical location: PCsspp
Report sent to printer.
Examples:
status bri-port 1c0701
status bri-port 1c0701 print
Page 1 of
STATUS BRI-PORT
Endpt Extension
1010
ISDN-BRI port address.
ISDN-BRI port is "in-service" or "out-of-service."
Specifies if maintenance testing is executing on the ISDN-BRI port
(y/n)
Feature
Logins
Defaults
Interactions
init
none
none
inads
craft
cust
nms
browse
1
SPE A
Endpt SPID
Service SPID?
1010
Issue 4 May 2002