Avaya Definity SI Maintenance Manual page 795

Table of Contents

Advertisement

AC-POWER
Table 10-4. System Technician-Demanded Tests: AC-Power — Continued
Emergency Transfer Query Test (#124) (c)
Cabinet Temperature Query Test (#122) (d)
External Alarm Lead Query Test (#120) (e)
Analog Ring Generator Initialization Test (#117) (f)
Analog Ring Generator Query Test (#118) (f)
1
D = Destructive, ND = Non-destructive
Notes:
a. Refer to "POWER" for a description of this test.
b. Refer to "CARR-POW" for a description of this test.
c. Refer to "EMG-XFER" for a description of this test.
d. Refer to "CABINET" for a description of this test.
e. Refer to "EXT-DEV ADMIN? N" or "EXT-DEV ADMIN? Y" for a description
of this test.
f. Refer to "RING-GEN" for a description of this test.
AC Power Query Test (#78)
This test queries the Maintenance/Tape Processor in a PPN in a system without
High or Critical Reliability, the Duplication Interface circuit pack in a High or Critical
Reliability system PPN, or the EPN Maintenance circuit pack in an EPN
multicarrier cabinet system for the status of AC power to the switch. In a
DC-powered system, this test should never fail.
555-233-123
Order of Investigation
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
Continued on next page
Issue 4 May 2002
1
D/ND
ND
ND
ND
ND
ND
10-9

Advertisement

Table of Contents
loading

Table of Contents