Avaya Definity SI Maintenance Manual page 995

Table of Contents

Advertisement

ATM-DCH (ATM D-Channel Port)
Hardware Error Log Entries and Test to Clear
Values
Table 10-73. ATM D-channel Error Log entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18 (a)
0
busyout port UUCSSpp
130 (b)
None
1793 (c)
Signaling Link Board Check
(#643)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
pp is for ports 9-32.
Notes:
a. Error Type 18: D-channel busied out; no calls possible over this D-channel.
b. Error Type 130: circuit pack removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
Check (#643). Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH maintenance object is test port UUCSSpp,
where pp is for ports 9-32.
Table 10-74. System Technician-Demanded Tests: ATM-DCH
Order of Investigation
Signaling Link Board Check (#643)
1
D = Destructive, ND = Nondestructive
555-233-123
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
Short Test
Long Test
Sequence
Sequence
X
X
Issue 4 May 2002
Test to Clear Value
2
test port UUCSSpp
release port UUCSSpp
test port UUCSSpp
test board UUCSS l
Continued on next page
1
D/ND
ND
10-209