Avaya Definity SI Maintenance Manual page 1371

Table of Contents

Advertisement

DIOD-DS1 (DS1 DIOD Trunk)
Three trunk service states are specified by DS1 DIOD trunk maintenance:
out-of-service
in-service
disconnect (ready-for-service)
Hardware Error Log Entries and Test to Clear
Values
Table 10-217. DS1 DIOD Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1(a)
57408
1(a)
57487
57476
57477
57485
15(b)
Any
Port Audit and
Update Test (#36)
18(c)
0
busyout trunk
<grp>/<mbr>
130(d)
None
257(e)
57392
DS1 CO Dial Tone
Seizure Test (#314)
513(f)
57393
DS1 Tie Trunk
Seizure Test (#136)
769(g)
57484
1025(h)
51200
1025
DS1 CO Dial Tone
Seizure Test (#314)
1281
Conference Circuit
Test (#7)
1537
NPE Crosstalk Test
(#6)
1793(i)
2049(j)
57473
57474
57475
555-233-123
The trunk is in a deactivated state and cannot be
used for either incoming or outgoing calls.
The trunk is in an activated state and can be
used for both incoming and outgoing calls.
The trunk is in an activated state but can only be
used for an incoming call.
Alarm
Associated Test
Level
Any
WARNING
WARNING
MIN/MAJ
MIN/MAJ
MIN/
WRN
MIN/
WRN
MIN/
WRN
On/Off
Board
Test to Clear Value
Any
test trunk <grp>/<mbr>
OFF
release trunk <grp>/<mbr>
ON
test trunk <grp>/<mbr>
2
OFF
2
OFF
OFF
test trunk <grp>/<mbr> r 2
3
ON
test trunk <grp>/<mbr> l r 4
3
ON
test trunk <grp>/<mbr> l r 3
3
test board PCSS l
Issue 4 May 2002
Continued on next page
10-585

Advertisement

Table of Contents
loading

Table of Contents