Maintenance Object Repair Procedures
Table 10-70. TEST #256 Service State Audit Test — Continued
Error
Code
Result
1114
ABORT
1116
ABORT
1117
ABORT
2100
ABORT
1113
FAIL
FAIL
PASS
Call State Audit Test (#257)
This test audits the internal call state by asking the far-end switch for the ISDN call
state. The test is particularly useful when you are trying to clear a hung call. If the
internal call state on the near-end differs from that on the far-end, the call is torn
down.
The ISDN specification allows up to 2 minutes for a reply. If a reply is not received
within the 2 minute window, the test logs a protocol time-out violation against the
associated signaling channel (ATM-DCH, Error Type 1).
NOTE:
PASS simply means that an appropriate message was composed and sent
to the far-end switch.
10-202
Issue 4 May 2002
Test
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
Trunk not in Out-of-Service/Far-end state and country protocol
other than 1
Service-state audit message outstanding
1. Wait 2 minutes, then try again.
Could not allocate needed resources
1. Retry the command up to 5 times at 1-minute intervals.
Signaling link failed
1. See the
''ATM-SGRP (ATM Signaling Group)''
ISDN-LNK (ISDN Signaling Link Port) maintenance objects.
Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
1. Wait 4 minutes, then check the Error Log for any new Error
Type 3073.
If there are none, both sides of the ISDN connection
agree on the service state. The negotiation succeeded.
If there is a new 3073 error, then the negotiation failed
(the request timed out).
Description/Recommendation
Continued on next page