CLSFY-PT (Call Classifier Port)
Tone Detector Audit/Update Test (#43)
A sanity audit is performed on the CLSFY-PT (Call Classifier Port).
Table 10-156. Tone Detector Audit/Update Test (#43)
Error
Code
none
2000
2100
555-233-123
Test
Result
ABORT
The system was not able to allocate all the resources needed
for this test.
1. Wait 1-minute, and repeat the command a maximum of 5
times.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Hardware audit failed.
1. Run the short test sequence via the test port PCSSpp
sh r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the
CLSFY-BD (Call Classifier circuit pack) containing the
defective CLSFY-PT (Call Classifier Port).
PASS
The (CLSFY-PT) Call Classifier Port has passed the sanity
inquiry.
Description/Recommendation