Avaya Definity SI Maintenance Manual page 818

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-12. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
1002
1003
1004
2000
2100
10-32
Issue 4 May 2002
Test
Result
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may have
time slots that are out-of-service due to TDM-BUS errors.
Refer to "TDM-BUS" to diagnose TDM-BUS errors.
1. If the system has no TDM-BUS errors and if it is not
handling heavy traffic, retry the command at 1-minute
intervals a maximum of 5 times.
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present, or some tone detectors may be out-of-service.
1. Resolve any "TTR-LEV" errors.
2. Resolve any "TONE-PT" errors. Try (a).
ABORT
The port was put in use during the test. The test has been
aborted.
1. Use the display port PCSSpp to determine the voice port
extension of the port.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before retesting.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Could not allocate the necessary system resources for this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page