ADX16A-PT (AUDIX Analog Line/Control Link)
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function.
Table 10-15. TEST #7 Conference Circuit Test
Error
Code
Result
ABORT
1000
ABORT
1004
ABORT
1018
ABORT
2000
ABORT
555-233-123
Test
Could not allocate the necessary system resources to run this
test.
(a)
System resources required to run test are not available. The port
may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
retesting.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
Test disabled by administration. This only applies to analog
stations.
1. To enable the test for the analog station being tested, enter
the change station <extension> command and change the
Test?
field on the Station Form from
Response to the test request was not received within the
allowable time period.
Description/Recommendation
Continued on next page
Issue 4 May 2002
n
to y.
10-39