Avaya Definity SI Maintenance Manual page 1369

Table of Contents

Advertisement

DIG-LINE (Digital Line)
Table 10-216. TEST #17 Station (Digital) Audits Test — Continued
Error
Code
6
1000
1392
2000
555-233-123
Test
Result
ABORT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for
this port. If this error type is present, the release the port
via the release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
System resources required to run this test are not available.
ABORT
This port is currently a TTI port and the test will not execute on
it.
1. Verify that the port is a TTI port using either the display
port command (the display shows that the port is a TTI
port) or the list config command (the display shows a t
for the port).
2. If either list config or display port indicate that the port is
not a TTI port, escalate the problem. If both commands
indicate that the port is a TTI port, the abort is correct, and
no action is necessary.
ABORT
Response to the test request was not received within the
allowable time period.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Station Audits passed. This Digital Port circuit pack is
functioning properly.
1. If complaints persist, investigate by using other port tests,
and by examining the station, wiring, and connections.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-583

Advertisement

Table of Contents
loading

Table of Contents