Avaya Definity SI Maintenance Manual page 1241

Table of Contents

Advertisement

CO-TRK (CO Trunk)
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop around and conference capabilities of a CO
port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones. Each tone is
transmitted separately through the loop and checked.
Table 10-168. TEST #33 Loop Around and Conference Circuit Test
Error
Code
7
129
131
133
1000
555-233-123
Test
Result
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Conference Circuit Test aborted.
ABORT
The 404-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
The 1004-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
The 2804-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
1. Retry the command at 1 minute intervals a maximum of 5
times.
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no
calls), check the error log for error type 769 (see the Error
Log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-455

Advertisement

Table of Contents
loading