Avaya Definity SI Maintenance Manual page 1160

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Power Unit Query Test (#127)
This test queries the Maintenance/Tape Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a system with High or Critical
Reliability, or the EPN Maintenance circuit pack in an EPN multicarrier cabinet
system for the status of pair of power units in the specified carrier. If both power
units are on and functioning, then the test passes. If both are not on and
functioning, it fails.
Table 10-142. TEST #127 Power Unit Query Test
Error
Code
1000
2000
2029
10-374
Issue 4 May 2002
Test
Result
ABORT
System resources required to run this test are not available.
1. Retry the command at one minute intervals a maximum of
5 times.
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to ABORT with error code 2000,
check for system powering problems with the A carrier
(PPN or EPN). Look for and resolve all AC-POWER and
CARR-POW alarms in a multicarrier cabinet system or
DC-POWER alarms in a single-carrier cabinet system.
Then, repeat the test.
3. If the test continues to ABORT with a 2000 error code,
check for and resolve all DUPINT (Duplication Interface)
errors in a Duplicated Option PPN, PR-MAINT
(Maintenance/Tape Processor) errors in a standard PPN,
or MAINT (EPN Maintenance circuit pack) errors in an
EPN. Then, repeat the test.
4. If the test continues to ABORT with a 2000 error code,
escalate the problem.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
555-233-123