Avaya Definity SI Maintenance Manual page 1279

Table of Contents

Advertisement

DATA-CHL (Data Channel)
Table 10-181. TEST #109 Data Channel Remote Maintenance Loop Around
Test — Continued
Error
Code
1006
ABORT
1016
ABORT
1018
ABORT
2003
ABORT
2004
ABORT
555-233-123
Test
Result
For this test, an Error Code of 1006 can have one of several
different meanings:
a. No other DATA-CHLs are administered and, therefore,
not available to place the call to the target DATA-CHL.
b. All other DATA-CHLs are busy and, therefore, not
available to place the call to the target DATA-CHL.
c. Could not allocate the necessary system resources to run
this test.
d. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if no other DATA-CHLs are administered (list
data-module).
2. If no other DATA-CHLs are administered, administer at least
one.
3. Determine if errors exist on links using target DATA-CHL
(status link).
4. If there are no errors, busyout the links (busyout link).
5. Retry the command at 1-minute intervals, up to 5 times.
6. Restore any busied out links.
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
Test disabled through software patch.
Internal system error
Internal system error
1. Check dial plan to ensure data channel extensions are set up
as local extensions rather than remote or UDP extensions.
2. Retry the command at 1-minute intervals, up to 5 times.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-493