Maintenance Object Repair Procedures
Hardware Error Log Entries and Test to Clear
Values
Table 10-106. BRI-BD Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
Any
18(b)
0
23(c)
0
257(d)
65535
513(e)
4352 to
4357
769(f)
4358
1025(g)
4363
1293
46088
to
to
1294 (h)
46096
1537 to
46082
1538 (i)
1793 (j)
46080
1794 (j)
46094
1795 (j)
46085
2306 (j)
3330 (k)
46083
3840 (l)
4096 to
4101
3843 (m)
46097
3999 (n)
Any
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
10-260
Issue 4 May 2002
Alarm
Associated Test
Any
Any
None
MINOR
busyout board
WARNING
PCSS
None
WARNING
Control Channel
MINOR
Loop Test (#52)
NPE Audit Test
(#50)
SAKI Sanity Test
MINOR
(#534)
MINOR
MINOR
MINOR
MINOR
LANBIC Receive
Parity Error
Counter Test
(#595)
MINOR
None
On/Off
Level
Board
Any
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
Test to Clear Value
test board PCSS sh r 1
release board PCSS
test board PCSS r 20
See footnote (h)
Continued on next page