Maintenance Object Repair Procedures
Digital Terminal Lamp Update (#16)
This test updates internal lamp states that can or cannot be shown on the actual
PC graphical user interface. The lamp updates run only if the station is in-service.
The status of the station is checked and the lamp updates are blocked from taking
place if the station is not in the in-service state. This test does not affect the status
of the Message Waiting lamp.
Table 10-204. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Test
Code
Result
ABORT
1
ABORT
3
ABORT
1000
ABORT
FAIL
PASS
10-556
Issue 4 May 2002
Description/Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
This port could have been busied out by system technician.
Look in the Error Log for Error Type 18 (port busied out) for this
port. If this error type is present, then release the port via the
release station <extension> command and run the test again.
Make sure that the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
Station could be in ready-for-service or out-of-service state.
Use status station command to verify state of station.
Make sure the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The
port could be busy with a valid call.
Use display port UUCSSpp to determine the station extension of
the port. Use status station to determine the service state of the
port. If the port is in use, wait until the port is idle before testing.
If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
The message to light all of the station lamps was sent
successfully to the port.
Continued on next page