Maintenance Object Repair Procedures
Table 10-170. TEST #844-848 Transmission Test — Continued
Error
Code
2056
8000
10-464
Issue 4 May 2002
Test
Result
ABORT
An error occurred while trying to obtain results from the TN771
circuit pack.
1. Test the TN771 circuit packs.
FAIL
Measured transmission performance was in the unacceptable
range as administered on the trunk group form. Retrieve a
measurement report via the list testcalls command. Make
sure that ATMS thresholds are set properly on page 4 of the
trunk group form. Besides the facility, test failures can be
caused by faulty test lines or switch paths. If the measurements
point to a facility problem, report the results to the trunk vendor.
FAIL
Measured transmission performance was in the marginal range
as administered on the trunk group form. This generally means
that the trunk is usable but has an undesirable amount of noise
or loss. If the user does not report unacceptable effects, it may
not be necessary to take any action. Retrieve a measurement
report via the list testcalls command. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group form.
Description/Recommendation