Dly-Mtce (Mo-Daily) - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Object Repair Procedures

DLY-MTCE (MO-DAILY)

MO Name (in
Alarm Log)
DLY-MTCE
DLY-MTCE
The DLY-MTCE maintenance object monitors daily translation saves. If a
translation save times out or fails to run, an error is logged against this
maintenance object.
Daily Maintenance Interference
All of the actions used in DEFINITY administration commands are listed in the
table below. The command actions that, while active, interfere with daily
maintenance are also indicated. They are the add, change, duplicate, remove,
and set commands. These commands are frequently used by customer
administrators while performing routine administration of DEFINITY.
Table 10-228. DEFINITY Command Actions
Likely to Disrupt
add
change
duplicate
remove
set
10-608
Issue 4 May 2002
Alarm
Level
Initial Command to Run
MINOR
NONE
MAJOR
NONE
If Save Fails
Three times in a row
Seven times in a row
Less Likely to Disrupt
backup
busyout
clear
display
enable
format
get
list
mark
monitor
netstat
Full Name of MO
DLY-MTCE
DLY-MTCE
Then System Raises
MINOR Alarm
MAJOR Alarm
ping
recycle
release
reset
restore
resume
save
status
test
upgrade
Continued on next page