Avaya Definity SI Maintenance Manual page 950

Table of Contents

Advertisement

Maintenance Object Repair Procedures
2. Performing a test board long when the circuit pack is in this state
3. The save/restore announcements command times out with:
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
10-164
Issue 4 May 2002
yields the following abort codes:
Ports 1 and 9 abort Test #206 with code 1024
Ports 1 and 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
Error encountered, can't complete request
busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
reset circuit pack using the reset board PCSS command
release circuit pack using the release board PCSS command