Avaya Definity SI Maintenance Manual page 998

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-77. ATM-INTF Error Log Entries
Error
Aux
Type
Data
Associated Test
23(a)
0
None
125(b)
None
217(c)
0
None
Notes:
a. Error Type 23: ATM Expansion Interface circuit pack is administered
through a change circuit-pack command, but has not been inserted into
the system. Insert the circuit pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit
pack is logically administered. To resolve this problem, either remove the
wrong circuit pack or insert the logically administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not
been given a personality. Remove the circuit pack or administer it using the
add atm pnc command or add atm trunk command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Failure of this test is not logged in the Error Log.
Order of Investigation
Control Channel Loop Around Test (#52)
1
D = Destructive, ND = Non-destructive
10-212
Issue 4 May 2002
Alarm
On/Off
Level
Board
WAR
OFF
MIN
ON
WAR
OFF
Short Test
Sequence
X
Test to Clear Value
Long Test
1
Sequence
D/ND
X
N