Maintenance Commands and Trouble-Clearing Aids
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No.
Result
Error Code
The following example shows the output for the test hardware-group system
with the background option selected.
test hardware-group system
Command started in background mode

test inads-link

This command attempts to make a call over the inads port on the maintenance
board to verify the INADS alarm notification process. In the default settings, the
system test the link to the first OSS telephone number. If there is an alarm
pending to be reported or the call is in progress or up, then the test aborts. If the
alarm origination to the OSS telephone number to be tested is disabled, then the
test generates an informative error and the test continues. The test waits 2
minutes before dialing the call to allow the remote maintenance technician to
logoff, thus freeing the line. A local SAT user entering the test inads-link
command does not need to log off for the system to place the call, but the
two-minute delay still exists.
8-446
Issue 4 May 2002
Port address (cabinet-carrier-slot-circuit)
The name of maintenance object
Alternate way to identify maintenance objects.
If the Object is The field contains
station
extension
trunk
xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
The test being executed
Test result: No Board, Extra Bd, Disabled, or Skipped
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
555-233-123