Avaya Definity SI Maintenance Manual page 1030

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-97. Packet Interface Loop Around Test (#598)
Error
Code
Result
1144
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
ANY
FAIL
PASS
ATM Board Reset (#1256)
This test is destructive.
This test checks the sanity of the angel processor using the Sanity and Control
Interface (SAKI) test (Common Port Board test #53). It resets the circuit pack if the
SAKI test fails and runs the test again.The ATM Board Reset test passes if SAKI
can successfully reset and retest the board.
Before running the SAKI test, you must:
Move synchronization off the ATM-TRK circuit pack
Busyout the ATM-TRK circuit pack
The test aborts if the ATM-TRK circuit pack is supplying synchronization.
10-244
Issue 4 May 2002
Test
The packet bus in the PPN has a major alarm against it.
Run display alarms and display errors.
Perform the PKT-BUS repair procedures associated with the
alarms.
Retry the command.
Test request timed out.
Retry the command up to 3 times at 1-minute intervals.
If the test fails repeatedly, run reset board UUCSS.
If the test continues to fail, replace the ATM-TRK circuit pack.
Internal system error
Could not allocate needed system resources.
Retry the command up to 5 times at 1-minute intervals.
Data packet not received correctly by the ATM Interface circuit
pack.
Retry the command up to 5 times at 1-minute intervals.
If the test continues to fail, replace the ATM-TRK circuit pack.
The Packet Interface Test passed.
Description/Recommendation
Continued on next page