Maintenance Object Repair Procedures
Battery Feed Test (also called Port Diagnostic
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery power, and detecting the resulting current.
Table 10-40. TEST #35 Battery Feed Test
Error
Code
1000
1004
1005
10-120
Issue 4 May 2002
Test
Result
Description/Recommendation
ABORT
Necessary system resources could not be allocated to run this
test.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
ABORT
System resources are unavailable. The port may be busy with
a valid call. This result is also reported for the system's
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station's
extension.
2. Enter status station extension to determine the service
state of the port.
3. If the port is in use, wait until the port is idle. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to determine
the service state of the port.
3. If the port is in use, wait until the port is idle before testing.
Retry the command at 1-minute intervals no more than 5
times.
4. If the test continues to abort, escalate the problem.
ABORT
This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.