Avaya Definity SI Maintenance Manual page 1200

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-155. TEST #42 Tone Detection Verification Test
Error
Code
none
1
1001
1002
1003
10-414
Issue 4 May 2002
Test
Result
ABORT
The system was not able to allocate all the resources needed
for this test OR there was an Internal System Error.
ABORT
The system could not allocate all the resources needed to test
the tones.
ABORT
The system was unable to put the Call Classifier port in the
appropriate mode to test it.
ABORT
The system could not allocate time slots for the test
connection. This situation could occur when the system is
heavily loaded. If the system is not heavily loaded, then test
the TDM-BUS via the test tdm [1|2] command. Refer to the
TDM-BUS (TDM Bus) Maintenance documentation for details.
1. Retry the command at one minute intervals a maximum of
5 times.
ABORT
The system could not allocate a Tone-Clock circuit pack for
the test connection. This situation could occur when the
system is heavily loaded or if a Tone-Clock circuit pack is not
present in the port network when this test is executed.
1. Verify the existence of a Tone-Clock circuit pack in the
same port network.
2. If a Tone-Clock circuit pack is missing, install one in the
same port network.
3. Allow approximately one minute for the Tone-Clock circuit
pack maintenance to run on the newly inserted
Tone-Clock circuit pack.
4. Retry the command at one minute intervals a maximum of
5 times.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading