Maintenance Object Repair Procedures
Synchronous Test Calls
You can initiate a synchronous outgoing test call (including a test call for
ISDN-PRI trunks) with these commands:
test trunk grp#/mbr# long [repeat #]
test board UUCSS long [repeat #]
test port UUCSSpp long [repeat #]
Table 10-72. TEST #258 ISDN Test Call
Error
Code
Result
4
ABORT
8
ABORT
1004
ABORT
1005
ABORT
1018
ABORT
1020
ABORT
1024
ABORT
10-204
Issue 4 May 2002
Test
Signaling channel problem
1. Look for errors or alarms against the
Signaling Group)''
maintenance objects.
TN230x circuit-pack problem
1. See the
''ATM-INTF (TN2305/6)''
B-channel in use.
1. See if a call is active. Run status trunk grp#/mbr#
command.
2. If the service state is In-Service/Idle, retry the test.
Bad configuration (for example, no Maintenance/Test circuit
pack)
1. Make sure that the Maintenance/Test Circuit Pack is inserted.
2. Repeat the test.
Test call disabled
1. Enable Maintenance on the Trunk Group form.
TN230x circuit-pack problem
1. See the
''ATM-INTF (TN2305/6)''
Maintenance/Test Digital Port in use
1. Wait until yellow and green LEDs on the Maintenance/Test
circuit pack are OFF.
2. Rerun the test.
3. If the problem persists, see the M/T-DIG (Maintenance/Test
Digital Port) maintenance object.
Description/Recommendation
''ATM-SGRP (ATM
and
''ATM-DCH (ATM D-Channel Port)''
maintenance object.
maintenance object.