Maintenance Object Repair Procedures
Table 10-26. TEST #7 Conference Circuit Test — Continued
Error
Code
1018
2000
2100
10-70
Issue 4 May 2002
Test
Result
ABORT
The test has been disabled via administration. The default for
the 'Test' field on the 'Station' form is 'y'; thus, you may want
to determine why this field has been set to 'n' on this station
(this may be due to the ringing application test 48, which can
be customer or terminal disturbing).
1. To enable the test for the particular analog station being
tested, enter change station extension and set the
'Test?' field on the station from 'n' to 'y.'
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
System resources required to run this test are not available.
1. Look for TONE-PT errors in the error log. If present, refer
to the TONE-PT Maintenance documentation.
2. If there are no TONE-PT errors in the error log, retry the
test at 1-minute intervals for a maximum of 5 times.
Description/Recommendation
Continued on next page