Avaya Definity SI Maintenance Manual page 1157

Table of Contents

Advertisement

CARR-POW (Carrier Port Power Unit) for AC-Powered
Systems
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery & Battery
Charger Query Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Order of Investigation
Battery & Battery Charger Query Test (#5) (a)
AC Power Query Test (#78) (b)
Power Unit Query Test (carrier E) (#127)
Power Unit Query Test (carrier D) (#127)
Power Unit Query Test (carrier A) (#127)
Power Unit Query Test (carrier B) (#127)
Power Unit Query Test (carrier C) (#127)
Emergency Transfer Query Test (#124) (c)
Cabinet Temperature Query Test (#122) (d)
External Alarm Lead Query Test (#120) (e)
Analog Ring Generator Initialization Test (#117) (f)
Analog Ring Generator Query Test (#118) (f)
1
D = Destructive; ND = Nondestructive
Notes:
a. Refer to POWER (Battery & Battery Charger) Maintenance documentation
for a description of this test.
b. Refer to AC-POWER (AC Power) Maintenance documentation for a
description of this test.
c. Refer to EMG-XFER (Emergency Transfer) Maintenance documentation
for a description of this test.
d. Refer to CABINET (Cabinet Sensors) Maintenance documentation for a
description of this test.
e. Refer to EXT-DEV (External Alarm) Maintenance documentation for a
description of this test.
f. Refer to RING-GEN (Analog Ring Generator) Maintenance documentation
for a description of this test. This test only shows up in the test sequence if
there is a TN768 Tone-Clock circuit pack in the port network being tested.
555-233-123
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Issue 4 May 2002
1
D/ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
10-371

Advertisement

Table of Contents
loading

Table of Contents