Avaya Definity SI Maintenance Manual page 1352

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-209. DIG-LINE Error Log Entries — Continued
Error Type Aux Data
2817(j)
Any
3840 (k)
40965
3840 (l)
40989
3841 (m)
41029
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
3
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
Notes:
a. Could experience a noisy port or link. This is an off-board problem detected
by the port circuit. Check for defective wiring, a defective voice terminal, or
move voice terminal closer to the switch (in terms of feet of wire from the
jack to the switch). If the problem still exists, replace the circuit pack. Once
the problem has been resolved, the alarm will be retired after a
predetermined amount of time.
b. This Error Type and Aux Data will occur when at least 15 off-board
problems have been detected with the link to the terminal. When an error
with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for defective wiring, a defective voice
terminal, or move voice terminal closer to the switch (in terms of feet of wire
from the jack to the switch). If the problem still exists, replace the circuit
pack. Once the problem has been resolved, the alarm will be retired after a
predetermined amount of time.
c. This error type is logged when the port in question is busied out by
maintenance personnel. Make sure port is released from busyout via the
release port PCSSpp command.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 21 minutes. To clear the error, reinsert or
replace the circuit pack.
10-566
Issue 4 May 2002
Associated Test
Alarm Level
None
None
None
None
On/Off
Board
Test to Clear Value
OFF
Continued on next page
555-233-123

Advertisement

Table of Contents
loading

Table of Contents