CARR-POW (Carrier Port Power Unit) for DC-Powered
Systems
Power Unit Query Test (#127)
This test queries the Maintenance/Tape Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a High or Critical Reliability system,
or the EPN Maintenance circuit pack in an EPN multicarrier cabinet system for the
status of the pair of port carrier power units in the specified carrier. If both port
carrier units are on and functioning, the test passes. If both are not on and
functioning, the test fails.
Table 10-144. TEST #127 Power Unit Query Test
Error
Code
1000
2000
2029
555-233-123
Test
Result
ABORT
System resources required to run this test are not available.
ABORT
Response to the test request was not received within the
allowable time period.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page