Maintenance Object Repair Procedures
NPE Audit Test (#50)
The system updates the network connectivity information for all the NPEs on the
circuit pack through message to the on-board microprocessor. This test is
non-destructive.
Table 10-175. TEST #50 NPE Audit Test
Error
Code
2100
1019
Control Channel Loop Around Test (#52)
This non-destructive test queries the circuit pack for its code and vintage. This test
also verifies the circuit pack records.
Table 10-176. TEST #52 Control Channel Loop Around Test
Error
Code
10-484
Issue 4 May 2002
Test
Result
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Circuit pack NPEs and translation updated.
Test
Result
ABORT
Could not allocate the necessary system resources to run this
test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
PASS
Successful communication with circuit pack.