ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Table 10-32. TEST #6 NPE Crosstalk Test — Continued
Error
Code
0
555-233-123
Test
Result
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Description/Recommendation
Continued on next page
Issue 4 May 2002
10-93