Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-10. EMBEDDED AUDIX Digital Port Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1(a)
40987
None
1(b)
1 to 20
None
15(c)
Any
None
18(d)
0
busyout port PCSSpp
23(e)
0
None
130(f)
None
257(g)
40971
None
513(h)
Any
None
1537(i)
40968
None
1793
Voice and Control
Local Loop TEST
(#13)
2049
NPE Crosstalk Test
(#9)
2305(j)
40967
None
3840(k)
40965
None
3840(l)
41029
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. The user may experience a noisy port or link. This is an off-board problem
that is detected by the port circuit. If this problem exists, replace the circuit
pack (see caution at the beginning of this section). Once the problem is
resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note a, above.
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Release the port with the release port
PCSSpp command.
10-26
Issue 4 May 2002
Alarm
Associated Test
Level
Any
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
MIN/ WRN
MIN/ WRN
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
OFF
OFF
OFF
release port PCSSpp
OFF
ON
test port PCSSpp sh
OFF
2
ON
test port PCSSpp l r 3
2
ON
test port PCSSpp l r 3
555-233-123