Status Access-Endpoint - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

status access-endpoint

spe-standby
spe-active
spe-maint
status access-endpoint
This command displays diagnoses internal software and helps to locate facilities
with which Access Endpoints communicate.
Action/
Object
Qualifier
status
extension
access-
print
endpoint
555-233-123
The default option for a High or Critical Reliability System. If a
restart occurs on active SPEs and the corresponding vector bit is
set, a core dump occurs on the standby SPE (after the standby
SPE has performed a memory refresh).
Option for a High or Critical Reliability System; default for simplex
SPE systems. If a restart occurs on active SPEs and the
corresponding vector bit is set, core dumps occur on the active
SPE. This option disrupts service.
Available for High or Critical Reliability Systems. If restarts occur
on active SPEs and the corresponding vector bit is set, core
dumps occur on standby SPEs without the standby SPE a
memory refresh.
Qualifier Description
extension number of the access endpoint
prints reports to SAT printers.
Examples:
status access-endpoint 25012
status access-endpoint 77868
status access-endpoint 66078 print
Feature
Logins
Defaults
Interactions
init
none
none
inads
craft
cust
nms
browse
Issue 4 May 2002
8-299