DID-TRK (DID Trunk)
Table 10-198. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
3
7
129
131
133
555-233-123
Test
Result
FAIL
The nonreflective 1004 Hz tone test of the port failed. An echo
was detected from the port. Poor quality transmission was
detected to or from the port. The problem may be off-board.
The conference capabilities of the port failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
The reflective 404-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
The reflective 1004-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
The reflective 2804-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
!
CAUTION:
The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems also
include incoming seizures or off-hook port seizures
during the test and, perhaps somewhat unlikely, noise
induced by adjacent electric power lines. Customers
having this problem should resolve it with their local
power company to temporarily alleviate the alarm
caused by the failure of this test. The test may be
disabled from trunk administration 'Test' field. This turns
off all testing for that trunk group except for tests 6 and
36.