Release Pri-Endpoint - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids

release pri-endpoint

The release-PRI endpoint command removes PRI endpoint ports (B-channels)
associated with specified PRI endpoint from maintenance busy states. Periodic
and scheduled tests resume on released ports. The switch attempts to negotiate
with the far-end PRI terminal adapter activating PRI endpoint port (B-channel).
Maintenance does background initialization testing on released ports. For details
of the test sequence, refer to [3].
Action/Object
Qualifier
release
extension
pri-endpoint
Output
The following output example is a display of the release pri-endpoint 22501
command. Assume that the PRI endpoint ports for extension 22501 are in cabinet
1, carrier B, slot 20, circuit 1 to 6.
release pri-endpoint 22501
Port
Maintenance Name Alt. Name
01B2001
PE-BCHL
01B2002
PE-BCHL
01B2003
PE-BCHL
01B2004
PE-BCHL
01B2005
PE-BCHL
01B2006
PE-BCHL
Command Successfully Completed
Field descriptions
Port
Maintenance
Name
Alt. Name
Result
Error Code
8-262
Issue 4 May 2002
Qualifier Description
extension number associated with
desired PRI endpoint.
page 1 of 1
COMMAND RESULTS
Result
22501
PASS
22501
PASS
22501
PASS
22501
PASS
22501
PASS
22501
PASS
Port address (cabinet-carrier-slot-circuit) of released
maintenance object.
PE-BCHL.
Alternate way to identify maintenance objects. (PRI endpoint
extension)
Success status of a busied out object (PASS, ABORT, FAIL)
System-generated description of a command failure.
Feature
Logins
Defaults
Interactions
init
none
none