Maintenance Object Repair Procedures
Table 10-201. DIG-IP-STN Digital IP Station Error Log Entries
Error
Aux
Type
Data
Associated Test
0
0
Any
1 (a)
Registration Status Inquiry
(#1372)
18 (b)
0
Busyout port or station
257 (c)
Signaling Path PING Test
(#1373)
(d)
Digital Terminal Lamp
Update (#16)
(e)
Digital Terminal Audit
Update (#17)
513 (f)
Any
Station Digital AUDIT Test
(#17)
1281
Any
Station Digital AUDIT Test
(g)
(#17)
1537
40968
(h)
2305 (i)
Any
None
2817 (j)
Station Hyperactivity
Notes:
a. Error Type 1: this error reports the registration status of the endpoint. If call
processing SW claims the endpoint is registered and receives keep-alive
handshakes from the endpoint, the test passes. If keep-alive handshaking
has failed, the test fails. If the user has intentionally un-registered from
Avaya DEFINITY Server, the station is now basically an AWOH station and
is no longer being maintained; no tests run for this station.
b. Error Type 18: this error type is logged when the port/station is busied out
by maintenance personal. Make sure the port/station is released from busy
via the release port/station command (IP terminal only).
c. Error Type 257: this error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpoint IP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times out,
the test fails.
10-552
Issue 4 May 2002
Alarm
On/Off
Level
Board
Any
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
Continued on next page
Test to Clear Value
test station extension
release port (or)
station
test port or station
test port or station
test port or station
555-233-123